Description
This analysis function computes the coherent scalar field for unpolarized rays and allows analysis of complex field quantities such as energy, amplitude, signed amplitude, real part, imaginary part, phase and wavefront.
NOTE: Polarized rays are ignored in this calculation.
Navigation
This command can be accessed in the following ways:
•Menu > Analysis > Coherent Scalar Wave Field
•Ctrl + Shift + W
•Toolbar button: 
Controls
|
Control
|
Inputs / Description
|
Defaults
|
|
Use This Analysis Surface
|
|
Use This Analysis Surface
|
Currently selected analysis surface
|
First surface in list
|
|
List of Available Analysis Surfaces
|
|
List of Available Analysis Surfaces
|
Lists the available analysis planes for use as the ray filter.
|
Valid analysis surfaces
|
|
Pre-Analysis Ray Operations
|
|
Delete old rays and recreate all active sources
|
If checked, existing rays are deleted, and new rays are created before the analysis proceeds.
|
Unchecked if rays exist. Checked if no rays exist.
|
|
Raytrace all active rays
|
If checked, any existing rays are raytraced before the analysis is performed.
|
Unchecked if rays exist. Checked if no rays exist.
|
|
Plot the rays as they are being raytraced
|
If checked the rays will be drawn to the 3D view when traced.
|
Unchecked
|
|
Post-Analysis Operations
|
|
Create Analysis Results Node (ARN)
|
Adds an Analysis Results Node (ARN) to the Analysis Results folder on the object tree. The ARN being created stores the results of, and information about, the analysis being performed.
|
Unchecked
|
|
Name Prefix
|
The name of the ARN on the tree will be formed by combining this name prefix with an automatically generated numeric value, ensuring that the resulting ARN has a unique name string.
|
CoherentScalarField
|
|
|
|
OK
|
Perform analysis and close dialog box.
|
|
|
Cancel
|
Discard analysis and close dialog box.
|
|
|
Help
|
Displays this help article
|
|
Application Notes
Multi-threaded operation
The Coherent Scalar Wave Field and its script equivalent are multi-threaded so that calculation times will decrease if you have a multi-processor PC. The number of processors used for the calculation is determined in the same manner as the raytrace multi-threading.
Multiple wavelengths
When a coherent field calculation encounters multiple wavelengths, the calculation will proceed using only the first wavelength which satisfies the ray filter criteria. A warning dialog will be displayed which provides the wavelength range and the value used in the calculation (to 7 significant digits). All other wavelengths are ignored.
Related Topics
ScalarField (script command)
ScalarFieldToFile (script command)
ScalarFieldToFileAS (script command)
Chart Viewer - Chart Controls
Coherent Wave Field - Show Computed Wavefront
Coherent Wave Field - Decompose Wavefront
|
Copyright © Photon Engineering, LLC
|
|