Navigation: Raytrace Properties > Reflect Specular

 

Reflect Specular

 

Contact Us: fredsupport@photonengr.com

 

 

 

Description


The Reflect Specular raytrace control allows only reflected rays to propagate if the flux (power) exceeds the specified thresholds. This control does not allow Total Internal Reflection.

 

 

Navigation


This feature can be accessed in the following ways:

Double mouse click the Reflect Specular node of the Raytrace Properties tree folder.

Right mouse click the Reflect Specular node of the Raytrace Properties tree folder and select "Edit a Raytrace Control Set" from the list menu.

In the Coating/Raytrace Control tab of a surface dialog, select the Reflect Specular raytrace control and press the "Edit/View" button.

 

Controls


Control

Inputs / Description

Defaults

Name

Name of the Raytrace Control.

Reflect Specular

Description

Alpha-numeric description of the Raytrace Control.

Allow reflected specular ray only

Ray Power Cutoff Thresholds

Specular Refl- Abs/Rel Power

Controls specular reflected ray cutoff.  Rays with power less than or equal to this value are not propagated.

0, 0

Specular Trans- Abs/Rel Power

Controls specular transmitted ray cutoff.  Rays with power less than or equal to this value are not propagated.

0, 0

Scatter Refl- Abs/Rel Power

Controls scattered reflected ray cutoff.  Rays with power less than or equal to this value are not propagated.

0, 0

Scatter Trans- Abs/Rel Power

Controls scattered transmitted ray cutoff.  Rays with power less than or equal to this value are not propagated.

0, 0

Absorbed- Abs/Rel Power

Controls absorbed ray cutoff.  Rays with power less than or equal to this value are not created.

0, 0

Intersection Count Cutoff

Total

This value sets the maximum number of surface intersections for each ray.  Maximum of 1,000,000.

1000

Consecutive

This value sets the number of consecutive intersections each ray can have with a single surface.

10

Ancestry Level Cutoff

Specular

This value sets the maximum number of Specular generations that can be split.

2

Scatter

This value sets the maximum number of Scatter generations that can be split.

1

Spec+Scat

When active, a ray will be suppressed if the sum of its specular and scatter ancestry exceed the specified value.

Unchecked (10)

Allowed Ray Operations

Allow reflected ray

Check this box to allow propagation of the reflected ray component.

Checked

Allow transmitted ray

Check this box to allow propagation of the transmitted ray component.

Unchecked

Allow Total Internal Reflection

Check this box to allow propagation a ray that undergoes Total Internal Reflection.

Checked

Allow reflected ray

Check this box to allow propagation of the reflected scatter component.

Checked

Allow transmitted ray

Check this box to allow propagation of the transmitted scatter component.

Checked

Allow absorbed ray

Creates an absorbed ray which remains on the surface (see Application Note below).

Unchecked

Parent Ray Specifier

Largest incoherent power

Check this radio button to allow FRED to determine the Parent ray following a surface intersection.

Selected

Transmitted

Check this radio button to always make the transmitted ray the Parent ray.

Not selected

Reflected

Check this radio button to always make the reflected ray the Parent ray.

Not selected

Monte-Carlo (1 ray only)

Check this radio button to invoke Monte-Carlo raytracing. Chooses either the transmitted, reflected or scattered ray based upon probability.

Not selected

 

OK

Accept settings and close dialog box.

 

Close

Discard Settings and close dialog box.

 

Apply

Apply Settings and keep dialog box open.

 

Help

Access this Help page.

 

 

 