Navigation: Scripting Reference Manual > Functions & Subroutines > GetSourcePosApodSuperGaussianExponent

 

GetSourcePosApodSuperGaussianExponent

 

Contact Us: fredsupport@photonengr.com

 

Description

This subroutine retrieves the exponent parameters from a source with the Super Gaussian position apodization function applied.

 

 

Syntax

GetSourcePosApodSuperGaussianExponents( src, eX, eY )

 

 

Parameters

src As Long

Node number of the source whose Super Gaussian position apodization parameters are being retrieved.

 

eX As Double

Retrieved Super Gaussian exponent in the X axis.

 

eY As Double

Retrieved Super Gaussian exponent in the Y axis.

 

 

Example

The following example demonstrates how Super Gaussian position and direction apodization parameters can be retrieved from a source node and reported in the output window.

 

Sub Main

 

    Dim src As Long

    src = FindFullName( "Optical Sources.Apodized Source" )

 

    Print ""

    Print "

 

    'Retrieve Super-Gaussian position apodization

    Dim p_wx As Double, p_wy As Double, p_x0 As Double, p_y0 As Double

    Dim p_eX As Double, p_eY As Double

    Dim p_n As Long, p_m As Long, p_mtype As Long

    If IsSourcePosApodSuperGaussian( src ) Then

 

        'Retrieve Super-Gaussian position apodization specifications

        GetSourcePosApodSuperGaussian( src, p_wx, p_wy, p_x0, p_y0 )

        GetSourcePosApodSuperGaussianExponents( src, p_eX, p_eY )

        GetSourcePosApodSuperGaussianMode( src, p_n, p_m, p_mtype )

 

        'Report the retrieved information

        Print ""

        Print "Super-Gaussian position apodization settings:"

        Print "Wx" & Chr(9) & p_wx

        Print "Wy" & Chr(9) & p_wy

        Print "X0" & Chr(9) & p_x0

        Print "Y0" & Chr(9) & p_y0

        Print "Exp X" & Chr(9) & p_eX

        Print "Exp Y" & Chr(9) & p_eY

        Print "Mode N" & Chr(9) & p_n

        Print "Mode M" & Chr(9) & p_m

        Print "Mode Type";

        Select Case p_mtype

        Case 0

            Print "Hermite"

        Case 1

            Print "Laguerre"

        Case 2

            Print "Laguerre Cosine"

        Case 3

            Print "Laguerre Sine"

        End Select

 

    Else

        Print "Source does not use Super Gaussian position apodization."

    End If

 

    'Retrieve Super-Gaussian direction apodization

    Dim d_eX As Double, d_eY As Double, d_xAng As Double, d_yAng As Double

    Dim d_xType As String, d_yType As String

    If IsSourceDirApodSuperGaussian( src ) Then

 

        'Retrieve Super-Gaussian direction apodization specifications

        GetSourceDirApodSuperGaussian( src, d_eX, d_eY, d_xType, d_yType, d_xAng, d_yAng )

 

        'Report the retrieved information

        Print ""

        Print "Super-Gaussian direction apodization settings:"

        Print "X Angle" & Chr(9) & d_xAng

        Print "Y Angle" & Chr(9) & d_yAng

        Print "Exp X" & Chr(9) & d_eX

        Print "Exp Y" & Chr(9) & d_eY

        Print "X Angle Type" & Chr(9) & d_xType

        Print "Y Angle Type" & Chr(9) & d_yType

 

    Else

        Print "Source does not use Super Gaussian direction apodization."

    End If

 

End Sub

 

 

See Also

Detailed Source Scripting Commands

GetSourceDirApodSuperGaussian

GetSourcePosApodSuperGaussian

GetSourcePosApodSuperGaussianMode

SetSourceDirApodSuperGaussian

SetSourcePosApodSuperGaussian

 

 

 

 

 