Description This command retrieves the minimum temperature stopping criteria value for a Simulated Annealing optimization. Note that this does NOT indicate that this stopping criteria is currently activated.
Syntax minTemp = GetMzrAnnealStopBelowMinTemperature()
Parameters minTemp (Double) Minimum temperature stopping criteria value for a Simulated Annealing optimization.
Example The following example retrieves the starting conditions for an optimization and prints the parameters to the output window.
Sub Main
Dim multiStarts As Long Dim startTemp As Double Dim stopSteps As Long Dim stopMinTemp As Double Dim tempReduceFrac As Double
multiStarts = GetMzrMultiStarts() startTemp = GetMzrAnnealStartTemperature() stopSteps = GetMzrAnnealStopAfterSteps() stopMinTemp = GetMzrAnnealStopBelowMinTemperature() tempReduceFrac = GetMzrAnnealTemperatureReduceFraction()
Print "Multi Starts: " & Chr(9) & multiStarts Print "Start Temp: " & Chr(9) & startTemp Print "Stop Steps: " & Chr(9) & stopSteps Print "Stop Min Temp: " & Chr(9) & stopMinTemp Print "Temp Reduc. Frac: " & Chr(9) & tempReduceFrac
End Sub